Programmable Multi Load System

     

Electronic Load-40kW

=> Specifically designed for discharge the thermal batteries.
=> Remote mode operation.
=> RS232 Interface with easy to user Application Software
=> Programmable Load Steps with Programmable sample rates.
=> Programmable Sample rates: 1ms; 10ms; 100ms,1000ms;
Channel Selection:
       => CH1: 30kW
       => CH2: 5kW
       => CH3: 5kW
       => CH1,CH2 Parallel: 10kW
       => CH1,CH2 Dual: 10kW
       => CH1,CH2,CH3 Triple: 40kW
Operating mode:
       => Constant Current
       => Constant Power
       => Constant Voltage
Protections:Over Voltage, Over Current, Over Power and Reverse Protection
Data Acquisitions :Current, Power, Voltage, Squib Current, Temperature
Terminations :By Time,By End Voltage,Forced Termination, Emergency Load Termination.